Model
|
On-Line
|
MHCM
2000M
|
MHCM
3000M
|
|
Output |
VA
Rating |
2000VA
|
3000VA
|
| Wattage
(100~120V) |
1400W
|
2000VA
|
|
Current (100~120V)
max. |
18.2A
|
27.3A
|
| Voltage
|
100V, 110V,
120V ¡Ó 2% |
| Frequency
|
50/60Hz Auto
Select |
| Waveform
|
Pure Sinewave
|
|
Harmonic Distortion |
Less
than 3% at full load (Linear load) |
|
Output Connections |
Hospital
Grade 5-15R, 5-20R |
|
Input |
Voltage
|
80V-145V/
160V - 275V |
| Frequency
|
45 - 65Hz
Autoselect |
| Input
Connections |
Hospital
Grade 5-20P |
NEMA
lL5-30 Locking Devices |
|
Runtime |
Full
Load |
5-7
min
|
| Half
Load |
15
min.
|
|
Transfer Time
|
INV
to Bypass /Bypass to INV |
Less than
4 msec. (2 msec. min.)/ Zero-Cross Transfer |
| Power
Failure |
0 msec, to
or from battery |
|
Battery |
Type
(Lead Acid maintenance free) |
12V/7AH |
| DC
Voltage |
72 VDC |
96 VDC |
| Recharge
Time |
5 - 8 hours
|
| Recharge
Current |
1.5A (max.)
|
| Efficiency
|
AC
to AC |
85%
min. |
| Audible
Noise |
 |
<
50 dBA
|
| Indicators
|
LED
Display |
LINE,
INV., BAT., BYPASS, FAULT, BAT./LOAD LEVEL |
| Auto
Restart |
 |
Yes
|
| DC
Start up |
 |
Yes
|
|
Protection
|
Overload
|
>110%
of full load with 15-20 sec. delay, 150% Immediately
|
| Over/Under
Voltage at I/P or O/P |
Inverter shutdown
protection |
| Phone
Jack |
RJ-11/RJ-45
(optional) |
| Short
Circuit |
Shut down
and won't transfer to bypass output, will work normally
again when short circuit be removed. |
|
Approved |
¡@ |
¡@ |
¡@ |
| Safety
|
UL 1778, CAN/CSA
C22.2 NO.107.1, UL 2601-1 |
| Emisson |
FCC PART15
Class.A |
| IMMUNITY
(Surge-Protection) |
IEEE C62.41-1991
CAT.A |
| Computer
Interface |
LAN/RS232
Interface |
Mains
fail, battery low and remote shutdown |
|
Mechanical
|
Dimensions
(W*H*D)(mm) |
190x320x500
mm
|
| Net
/Gross (kgs) |
32.4/36.4
|
38.2/42.2 |
|
Environment
|
Temperature
|
0 - 40
C |
| Humidity
|
0 - 95% Non-Condensing
|